Short Course on Repairs – Covering The Basics

Vital Insights On The Operations Of Ice Rink Refrigeration Systems

In these modern times the demand for recreational ice equipment has experienced an upshot. The onus is on the manufacturers of ice rink refrigeration systems to up their game in terms of provision of top notch appliances.

Government has put in place stringent regulations that are to be met by the makers of the systems. Customers expect nothing short of sterling quality on the products they purchase.

The underlying function of refrigeration is about removing heat and creation of cold conditions. Therefore, the basic comprehension of heat transfer is essential.

In essence the movement of heat will always be from a warm place to a cooler one. Refrigeration procedures take the forms of indirect and direct methods.

A liquid refrigerant is used in the case of indirect process of refrigeration. It functions by absorbing heat from a secondary fluid which subsequently removes heat from a sports arena

Direct refrigeration functions by pushing the primary refrigerant to the pipes that are laid on the rink floor. Despite the latter method posing as more likeable, it is not the choice of majority of refrigeration experts.

Since the refrigeration specialists will want a situation where they will be able to regulate the harmful coolers, the indirect method fits the bill. The pollutants include ammonia and R-22 which falls in the category of Freons.

The toxins have the capacity to reach out to the whole playing perimeter. There is a higher chance that the harmful elements will leak out. It will not be possible to tell of a leak from Freon as it has no odor.

The pervasive smell of ammonia makes it less difficult to know if a leak is present. The commonly used brine in indirect methods of refrigeration is glycol and saline solution. The advantage of the calcium chloride is its efficiency in transferring of heat.

The standard and effectiveness of the ice rink refrigeration system is judged by how well the location underneath the ground has been done. In order to get the accurate measurements of the ice surface, the use of infrared camera is employed.

Computer systems are used to dictate the required response from the ice rink refrigeration systems if there are fluctuations in temperatures. In the ice recreational industry computers can be used to receive information from as many as forty sensors in a playing arena.

The ice rink refrigeration plants can be programmed to factor in usage schedules. When there are programmed shutdowns during the night or holidays, energy is saved in significant proportions.

Setting up of ice rink refrigeration plants is obviously an intricate procedure. It is therefore essential that people planning to install the systems hire competent rink operators.

5 Takeaways That I Learned About Repairs

The 4 Most Unanswered Questions about Ice